Frymaster Gas Rethermalizers FBRA18 Series User Manual

Page 26

Advertising
background image

5-5

BURNERS DO

NOT LIGHT.

Verify that correct setpoint has

been programmed, that main gas

supply valve is open, and that

equipment gas valve is set to ON.

Press ON/OFF button.

Did burners

light?

Problem

resolved.

Use bottlebrush to clean low water
sensor. If burners still do not light,

remove the cover over the water

sensors and thoroughly clean them

with a Scotchbrite or similar nylon pad.

Did burners

light?

Problem

resolved.

Open control panel by

removing screws in

each upper corner.

Is HEAT LED

on interface board

illuminated?

Problem is with the gas

supply or ignition system.

Call FASC.

Problem is with a

failed interface board or a

malfunctioning computer.

Call FASC.

Yes

No

Yes

No

Yes

No

Advertising
This manual is related to the following products: