Frymaster Gas Rethermalizers FBRA18 Series User Manual
Page 43
6-16
6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units
UNIT IS CONNECTED TO
POWER SUPPLY, DRAIN
VALVE IS FULLY CLOSED,
NO WATER IS IN POT,
CONTROLLER IS ON.
Is POWER
LED lit?
Is WATER
LED lit?
Is unit filling
with water?
Once water
reaches upper water
level sensor, does filling stop
and WATER LED
go out?
Water leg of 24V
circuit is OK.
Is WATER
LED lit?
Most probable cause is dirty upper
water level sensor, but could also be a
loose connection between sensor and
interface board, or a failed interface
board.
Most probable cause
is failed solenoid, but may
also be a failed water relay
on interface board.
Most probable cause is
a failed solenoid, but may
also be a failed water relay on
interface board or failed
interface board.
Ensure upper water level
sensor is not grounded (i.e., 24VAC
present across sensor and cabinet). If
sensor is not grounded, most
probable cause is failed
interface board.
Go to
"A".
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No