2 5.2 troubleshooting guides – Frymaster Gas Rethermalizers FBRA18 Series User Manual

Page 23

Advertising
background image

5-2

5.2

Troubleshooting Guides

COOKPOT DID NOT FILL

WHEN UNIT WAS TURNED ON.

WATER SUPPLY TO UNIT

VERIFIED TO BE ON.

Did anything appear

in controller display when unit

was turned on?

Open control panel by

removing screws in

each upper corner.

Is WATER

LED on interface board

illuminated?

Probable causes are a failed

water solenoid or a failed

interface board.

Call FASC.

Use bottlebrush to

clean water level

sensors.

Did LED

illuminate?

Did unit begin

to fill?

Problem

resolved.

Probable causes are a failed

interface board or

failed/loose high-level water

sensor wiring.

Controller is not functioning.

Probable causes are failed 12V

transformer, failed interface

board, or failed controller.

Yes

No

Yes

No

Yes

No

No

Yes


NOTE: This guide applies

to FBRA18 units only.