6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units (Continued)

NOTE: All voltage measurements involving the

gas valve leg of the 24V circuit must be made

within 4 seconds of unit calling for heat. If unit

does not fire within 4 seconds, ignition modules

will lock out and controller must be turned off

then back on to reset.

A

Is 24VAC

present on N/O

terminal of latch

relay?

Is 24VAC

present on COM

terminal of latch

relay?

Is 24VAC

present on J1 pin

3?

When water level

is above lower water level

sensor, is CYCLE LED lit?

Go to

"B".

Go to

"C".

Probable causes are failed

wiring between terminal block

and computer, or failed

computer.

If 12VDC is applied across coil,

probable cause is failed relay. If not,

probable cause is failed wiring between

controller and latch relay or failed

controller.

Probable causes are failed

24V transformer or failed wiring

between transformer box and

component box.

Yes

No

Yes

No

Yes

No

Yes

No