Restore factory defaults: test button, Restore factory – Intermate 100 User Manual

Page 223

Advertising
background image

Intermate100 and Intermate101 Print Server Administration Manual

223

Overview of Types of Resets: Restore Factory Defaults: TEST Button

32.3.

Restore Factory Defaults: TEST Button

General Information

You can do two types of resets. The difference between them
depends on how long you hold the Test Button before letting
go.

Use a pointed object to press the Test Button in. We recom-
mend having the print server attached to a printer when you do
a reset. It is easier to work with, and the operation will print a
confirmation page which can be quite useful.

Intermate100

If you are not good at counting seconds, you should make sure
you can see a watch or clock that shows seconds.

a

Turn the unit off by pulling the power supply
jack out of the print server.

b

Press the TEST Button.

c

Put the jack back in while you keep holding the
Button for:

d

When you let go of the Button, a confirmation
page will be printed if the reset has been
successful.

e

Reboot. A hardware reboot is easiest— use
the power supply jack to power the print server
Off and then On.

number of seconds:

Result

less than 15 sec.

Reset IP address to 0.0.0.0, subnet mask to 255.255.255.0
and default gateway to 0.0.0.0

more than 30 sec.

Restore All Defaults.
This is just like the remote “Restore All Defaults”.