Juniper Networks MX480 User Manual

Page 155

Advertising
background image

Action

On a regular basis:

Check the LEDs on the craft interface directly above each DPC slot. The green LED
labeled

OK

lights steadily when a DPC is functioning normally.

Check the

OK/FAIL

LED on the DPC. For more information, see

MX Series 3D Universal

Edge Routers Line Card Guide

. If the DPC detects a failure, the DPC sends an alarm

message to the Routing Engine.

Check the status of installed DPCs by issuing the CLI

show chassis fpc

command to

check the status of installed DPCs. As shown in the sample output, the value

Online

in the column labeled

State

indicates that the DPC is functioning normally:

user@host>

show chassis fpc

Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 41 9 0 1024 15 57
1 Online 43 5 0 1024 16 57
2 Online 43 11 0 1024 16 57
3 Empty
4 Empty
5 Online 42 6 0 1024 16 57

For more detailed output, add the

detail

option. The following example does not specify

a slot number, which is optional:

user@host>

show chassis fpc detail

Slot 0 information:
State Online
Temperature 41 degrees C / 105 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-07-10 12:28:33 PDT
Uptime: 1 hour, 33 minutes, 52 seconds
Max Power Consumption 368 Watts
Slot 1 information:
State Online
Temperature 43 degrees C / 109 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-07-10 12:28:38 PDT
Uptime: 1 hour, 33 minutes, 47 seconds
Max Power Consumption 249 Watts
Slot 2 information:
State Online
Temperature 43 degrees C / 109 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-07-10 12:28:40 PDT
Uptime: 1 hour, 33 minutes, 45 seconds
Max Power Consumption 335 Watts
Slot 5 information:
State Online
Temperature 42 degrees C / 107 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB

131