Figure 122: Connecting DC Power to the Router

Related

Documentation

Preventing Electrostatic Discharge Damage to an MX480 Router on page 248

MX480 DC Power Supply Description on page 44

Replacing an MX480 AC Power Supply Cord

1.

Disconnecting an MX480 AC Power Supply Cord on page 235

2.

Connecting an MX480 AC Power Supply Cord on page 236

Disconnecting an MX480 AC Power Supply Cord

To disconnect the AC power cord:

1.

Switch off the dedicated customer site circuit breaker for the power supply, and
remove the power cord from the AC power source. Follow the instructions for your
site.

2.

Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.

3.

Move the AC input switch next to the appliance inlet on the power supply to the off (

O

)

position.

4.

Remove the power cord from the power supply.