Upgrading the scb in the master routing engine – Juniper Networks MX480 User Manual

Page 204

Advertising
background image

As only one SCB has been upgraded, the alarm indicates that the SCBs are of mixed
type. This alarm is cleared after all the control boards are upgraded.

Upgrading the SCB in the Master Routing Engine

To upgrade the SCB in the master Routing Engine:

1.

Ensure a Graceful RE Switchover (GRES) to gracefully switch between the master
and backup Routing Engines, so that the backup RE becomes the master RE, by issuing
the

request chassis routing-engine master switch

command.

2.

Log in to the new master Routing Engine after the switchover.

3.

Switch the configuration mode to ensure that you are still in configure exclusive mode
by issuing the

exit

command and then the

configure exclusive

command, from the old

master Routing Engine.

4.

Log in to the current master Routing Engine again and issue the

configure exclusive

command.

5.

Power down the backup Routing Engine from the master Routing Engine by issuing
the

request system power-off other-routing-engine

command.

6.

Ensure that the Routing Engine is powered down by issuing the

show chassis

routing-engine 0

command.

user@host>

show chassis routing-engine 0

Routing Engine Status:
Slot 0:
Current State Present

Verify that the Current State is Present, which indicates that the Routing Engine is
offline.

7.

Take the first fabric plane of the backup Routing Engine offline by issuing the

request

chassis fabric plane 0 offline

command. SCB0 has four fabric planes numbered, 0, 1,

2, and 3.

8.

Verify that the fabric plane is offline by issuing the

show chassis fabric summary

command.

user@host>

show chassis fabric summary

Plane State Uptime
0 Offline
1 Online 3 minutes, 45 seconds

Verify that the State of Plane 0 is Offline.

9.

Take the remaining fabric planes offline by issuing the

request chassis fabric plane

1/2/3 offline

command—that is, by changing the fabric plane number each time. Verify

that the fabric planes are offline by issuing the command given in Step 4.

10.

Take the SCB in slot 0 offline by issuing the

request chassis cb offline slot 0

command.

11.

Verify that the control board is offline by issuing the

show chassis environment cb 0

command:

user@host>

show chassis environment cb 0

Copyright © 2013, Juniper Networks, Inc.