Maintaining the mx480 power supplies, Figure 78: do not stack fpcs – Juniper Networks MX480 User Manual

Page 171

Advertising
background image

CAUTION:

To prevent damage when storing FPCs:

Never lay an FPC component-side down.

Figure 78: Do Not Stack FPCs

Never stack an FPC under or on top of any other component (see

Figure

78 on page 147

).

Related

Documentation

MX480 Flexible PIC Concentrator (FPC) Description on page 16

MX480 FPC Terminology on page 143

Holding an MX480 FPC on page 144

Maintaining the MX480 Power Supplies

Purpose

For optimum router performance, verify the condition of the power supplies.

Action

On a regular basis:

Check the status of the power supplies by issuing the

show chassis environment pem

command. The output is similar to the following:

user@host>

show chassis environment pem

PEM 0 status:
State Online
Temperature OK
AC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
59 0 0 0
PEM 1 status:
State Online
Temperature OK
AC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
59 18 1062 42

Make sure that the power and grounding cables are arranged so that they do not
obstruct access to other router components.

147

Copyright © 2013, Juniper Networks, Inc.

Chapter 12: Maintaining MX480 Router Hardware Components