Installing an mx480 dual-wide mic, Figure 109: removing the septum – Juniper Networks MX480 User Manual

Page 236

Advertising
background image

Installing an MX480 Dual-Wide MIC

To install a dual-wide MIC (see

Figure 110 on page 213

):

1.

Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.

2.

Remove the septum, if necessary (see

Figure 109 on page 212

):

a.

Place the MPC on a flat surface (if necessary, remove the MPC from the router as
described in

“Removing an MX480 MPC” on page 204

).

b.

Remove the four screws labeled

S

on the bottom of the MPC.

c.

Remove the two screws labeled

S

on the top of the MPC.

d.

Slide the septum towards you and out of the MPC.

e.

Store the septum and screws for later use.

f.

Install the MPC as described in

“Installing an MX480 MPC” on page 206

.

Figure 109: Removing the Septum

g005040

Remove four screws
on bottom.

MPC

Remove two
screws on top.
Slide septum
forward.

3.

If the MIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver
on the faceplate. Install a cap if necessary.

4.

Pull the ejector lever above both MIC slots away from the router.

5.

Align the rear of the MIC with the guides located at the corners of the MIC slot.

6.

Slide the MIC into the MIC slot until it is firmly seated in the chassis.

CAUTION:

Slide the MIC straight into the slot to avoid damaging the

components on the MIC.

7.

Verify that the ejector levers are engaged by pushing them toward the router.

8.

If the MIC uses fiber-optic cable, remove the rubber safety cap from each transceiver
and the end of each cable.

Copyright © 2013, Juniper Networks, Inc.

212

MX480 3D Universal Edge Router Hardware Guide

Advertising