Polycom RMX 1000 User Manual

Page 158

Advertising
background image

Polycom RMX 1000 User Guide



18-3

View Device Information

Enter show after the prompt # to view the current device information,
including the system information, license information, interface information
and IP address.

Idle Timeout Setting

Enter keepalive<timeout> after the prompt # to modify the keep-live
timeout setting. If no operation was executed in the defined time interval, the
device will time out and exit.

Table 18-1

Parameters Description

Parameter

Description

timeout

Defaults to 120 seconds and can be modified to any value in the range

of 5 – 600 seconds

[Example] Set the timeout time to 60 seconds:

Reboot Device

Enter reboot after the prompt # to reboot the device.

Restore Password

Enter reset password after the prompt "#" to restore the user password for
Web login to the default password(POLYCOM). The system will display the
prompt “Are you sure?”, Enter “Y” to continue, or enter “N” to cancel.

After resetting the password, the RMX 1000 must be restarted in order for the
new settings to take effect.

[Example] Restore the Web login password to the default configuration:

Restore System Configuration

Enter reset config after the prompt "#" to restore the system to the default
configuration. The system will display the prompt “Are you sure?”, Enter
“Y” to continue, or enter “N” to cancel.

Advertising
This manual is related to the following products: