Polycom RMX 1000 User Manual

Page 50

Advertising
background image

Polycom RMX 1000 User Guide



4-11

Figure 4-6

Recording Parameter Setup Interface

The table below explains the configuration parameters.

Table 4-12

Conference Recording Configuration

Parameter

Description

Enable Recording

If an RSS 2000 is available on your network, you can select

this option to enable the recording function.

Start

Select the start time of the conference recording:

ƒ

Immediately – The recording automatically starts

immediately after the first participant joins the conference.

ƒ

Upon Request – The operator or chairperson starts the

recording manually. After this option is selected, the

recording can be manually started through the Web interface

or DTMF function. For more information, see Recording
Control

.

Enable Recording

Indication

If this option is selected, the endpoint screen displays the

recording indicator icon to inform participants that the

conference is being recorded:

Note:

Recording indication is not supported in video switching

conference and HD 720p conference.

Terminate
conference if
recording fail …

If this option is selected, the system will terminate the

conference when the recording fails or there is no endpoint in

the lobby.

Audio Only

If this option is selected, only the audio will be recorded.

The recording parameters can be set here only after the IP address of the RSS

2000 is configured on the Recording Link interface. For how to set Recording Link,

see Recording Setup.

The Recording Link occupies one conference resource.

If the encryption function is enabled in the Conference Profiles->General

interface, recording will succeed only when the RSS 2000 also supports

encryption.

Advertising