L_CamStretchFeed - stretching/compressing the position (relative)

182

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameter

Parameter

Possible settings

Information

C05440/1

String of digits

Position unit

• Read only

C05440/2

String of digits

Speed unit

• Read only

C05447

-214748.3647

Unit

214748.3647 Input position

• Display of the dnPosIn_p input si-

gnal in the real unit of the machi-

ne.

C05448

-214748.3647

Unit/t

2

214748.3647 Input acceleration feedforward cont-

rol

• Display of the dnAccIn_x input si-

gnal in the real unit of the machi-

ne.

C05449

-214748.3647

Unit

214748.3647 Feed length

• Display of the dnFeedLength_p in-

put signal in the real unit of the

machine.

C05450

-214748.3647

214748.3647 Effective stretch factor

C05451

-214748.3647

Unit

214748.3647 Starting position

• Display of the dnStartPos_p input

signal in the real unit of the ma-

chine.

C05455

-214748.3647

Unit

214748.3647 Output position

• Display of the dnPosOut_p output

signal in the real unit of the ma-

chine.

C05456

-214748.3647

Unit/t

214748.3647 Output speed

• Display of the dnSpeedOut_s out-

put signal in the real unit of the

machine.

C05457

-214748.3647

Unit/t

2

214748.3647 Output acceleration feedforward

control

• Display of the dnAccOut_x output

signal in the real unit of the ma-

chine.

C05458/1

-214748.3647

Unit

214748.3647 Stretched position

• Display of the dnStretchPos_p out-

put signal in the real unit of the

machine.

C05458/2

-214748.3647

Unit

214748.3647 Stretched feed length

• Read only

C05459

Status messages:

Status (bit coded)

• Bits that are not itemised are re-

served for future extensions.

• The bError error output will only

be set to TRUE if an error message

(bit 16 ... 31) is issued.

• Bit 31 is the default setting if one

or more other error bits (bit 16 ...

30) are set.

bit 10 Zero crossing active

Error messages:

bit 16 dnStartPos_p is beyond the cycle
bit 17 Initial speed too high
bit 23 Invalid axis data structure
bit 24 Stretched position too great
bit 31 General error