Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

85

3

Working with the FB editor

3.4

Creating/reconfiguring the interconnection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Danger!

In case a task overflow occurs, the brake can be configured to "open". This setting should

be used with care as the brake is then forcibly opened and does not close even if the drive

controller is inhibited!

Note!

• To render the changes effective within the controller, the project has to be updated,

and the changed application has to be transferred to the controller.

• During the reset or download of an application, all output signals are set to LOW level

or 0 V for a short time (the state bus, in contrast, is set to HIGH level due to harware

inversion).