5function blocks – Lenze E94A User Manual

Page 356

Advertising
background image

5

Function blocks

5.95

L_LdSetAxisVelocity - master value processing

356

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Identifier/data type

Value/meaning

dnState

DINT

Status

bits4 Position change per cycle too big

bits10 Zero crossing active
bits14 Internal limitation for calculation

Bit15 Error
bit16 Starting position is beyond the cycle

bits17 Error in the master signal (position or speed)
bits18 No cycle available

Bit 19 Maximum speed = "0"

bits20 Position of the touch probe sensor is beyond the cycle
bits21 Input error (e.g. impermissible position jump or inverse direction of

motion)

bits23 No valid axis data structure

bZeroPos

BOOL

Status signal "Zero position/zero crossing"

FALSE Master value is at any position in the master value cycle (register).

TRUE Permanently:

Master value is at the zero position of the master value integrator.

For one cycle:

Zero crossing of the master value integrator.

bTpDiffRecogn

BOOL

Status signal "Touch probe correction is active"

FALSE Touch probe correction is not active or already executed in the cur-

rent cycle.

TRUE Touch probe correction is active or not yet completed via the ramp

function.

dnDifference_p

DINT

Difference between dnTpPos_p and the position measured after detecting a touch

probe in [inc].

dnTpTpDistance_p

DINT

Distance between the last two touch probes in [inc]

• For instance to measure the real master value register.

dnTpDistance_p

DINT

Distance between the detected touch probe and the zero point of the integrator in

[inc]

dnSpeedOut_s

DINT

Master speed output in [rpm]

• C05036 indicates the master speed in the real unit of the machine.

dnPosOut_p

DINT

Master position output (position value of the master value integrator) in [inc]

• C05043 indicates the master position in the real unit of the machine.