Working with the FB editor

3.4

Creating/reconfiguring the interconnection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Sequence

1. If the current status of the FB Editor does not correspond to the device update executed last, first

the available function for updating a single device is called.

• This generates all files to be transferred to the device.
• A note may appear that first the networks should be updated.

2. If there was no online connection to the device yet, it will be established now.
3. A note appears that the controller is automatically inhibited for this function and the applicati-

on is stopped and the application will be automatically started after the transfer and the cont-

roller will be enabled.

4. The »Engineer« checks if the function is supported by the device and if the memory available in

the device is sufficient.

• If not, the function is closed with a corresponding note. In this case, use the regular function

"Download program".

5. The controller is inhibited and the function is stopped.
6. The application is transferred to the volatile memory of the device.
7. After successful download:

• The transferred application is started automatically and the controller is enabled.
• The value "99" is displayed in C00007 (active application).
• The "Application program volatile in the device" is displayed in the FB Editor status bar .

Tip!
When an online connection has been established, the parameters of the application stored

in the volatile memory can be read and changed using the »Engineer« as usual if the corre-

sponding »Engineer« project is open.