Function blocks

5.114

L_PosSequencer - sequence control

442

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.114.3.3 Action type "Switching"

In order to switch digital output signals 25 actions of type "Switching" are available.

• Each action can set two selectable bits of the output signal dwDigitalOutputs to "0" or "1" inde-

pendently of each other.

Action call (entry in the sequence table)

with action number xxx = 001 ... 025

Parameter
The available actions 1 ... 25 are indicated via the subcodes 1 ... 25.

Parameter

Possible settings

Information

C04520/1...25

Output for A switching

0 Switching is deactivated.
1 Sequencer output 1

(Bit 0 of dwDigitalOutputs)

2 Sequencer output 2

(Bit 1 of dwDigitalOutputs)

... ...

32 Sequencer output 32

(Bit 31 of dwDigitalOutputs)

C04521/1...25

Signal state for A switching

0 Set bit to "0".
1 Set bit to "1".

C04522/1...25

Output for B switching

0 Switching is deactivated.
1 Sequencer output 1

(Bit 0 of dwDigitalOutputs)

2 Sequencer output 2

(Bit 1 of dwDigitalOutputs)

... ...

32 Sequencer output 32

(Bit 31 of dwDigitalOutputs)

C04523/1...25

Signal state for B switching

0 Set bit to "0".
1 Set bit to "1".