5function blocks – Lenze E94A User Manual

Page 433

Advertising
background image

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

433

5

Function blocks

5.114

L_PosSequencer - sequence control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

dwBranch3

DWORD

Input signal for action 3 of type "Variable branch"

• Display parameter: C04692/3

• If the positioning program contains the action 3 of type "Variable branch", a

branch is carried out depending on the value applied to this input.

0 Branch to the next step.
1 Branch to the step defined in C04540/3.
2 Branch to the step defined in C04541/3.

... ...

20 Branch to the step defined in C04559/3.

> 20 Branch to the next step.

dwBranch4

DWORD

Input signal for action 4 of type "Variable branch"

• Display parameter: C04692/4

• If the positioning program contains the action 4 of type "Variable branch", a

branch is carried out depending on the value applied to this input.

0 Branch to the next step.
1 Branch to the step defined in C04540/4.
2 Branch to the step defined in C04541/4.

... ...

20 Branch to the step defined in C04559/4.

> 20 Branch to the next step.

dwBranch5

DWORD

Input signal for action 5 of type "Variable branch"

• Display parameter: C04692/5

• If the positioning program contains the action 5 of type "Variable branch", a

branch is carried out depending on the value applied to this input.

0 Branch to the next step.
1 Branch to the step defined in C04540/5.
2 Branch to the step defined in C04541/5.

... ...

20 Branch to the step defined in C04559/5.

> 20 Branch to the next step.

dwDigitalInputs

DWORD

Sequencer inputs 1 ... 32 (bit coded)

• The action types "Positioning", Branching", "Waiting" and "Stand-by" have the pa-

rameter "Input for...". If this is non-zero, it describes the number of the sequencer

input where the positioning program awaits the level defined before it executes

the action.

• For the transmission of individual control signals a BOOL-to-DWORD converter

can be connected to this input.

• Display parameter: C04693/1

bits0 Sequencer input 1
bits1 Sequencer input 2

... ...

bits31 Sequencer input 32