Parameter

17.2.22

LS_SetError_1

Parameterisable responses to user-defined events are tripped.

17.2.23

LS_SyncManagement

Output of status information for synchronising the internal time base.

17.2.24

LS_WriteParamList

Writing to a configurable list which contains up to 32 local parameters.

Note!

The real length of the low or high level at the bSquareWave output is always 1 ms higher

than set in

C00400/1

or

C00400/2

. If "0 ms" is set, a level with a length of 1 ms is created

length, for instance, and if "1000 ms" is set, a level with a length of 1001 ms is created.

Parameter

Possible settings

Info

C00400/1

0

ms

60000 Length of the low level (break) + 1 ms

• For output bSquareWave

• Lenze setting: 1000 ms

C00400/2

0

ms

60000 Length of the high level + 1 ms

• For output bSquareWave

• Lenze setting: 1000 ms

C00400/3

(from version 06.00.00)

0

ms

60000 Delay of the status bFirstCycleDone

• Lenze setting: 100 ms

For a detailed description see the main chapter "Diagnostics & error management":

"LS_SetError_1" system block

( 471)

For a detailed description see main chapter "Synchronisation of the internal time base of

the controller":

Internal interfaces | System block "LS_SyncManagement"

( 576)

For a detailed description see the main chapterl "

Parameter change-over

".

( 577)