In c, 8basic drive functions (mck) – Lenze 8400 StateLine User Manual

Page 416

Advertising
background image

8

Basic drive functions (MCK)

8.4

Holding brake control

416

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

[8-11] Close holding brake in automatic mode with actual value monitoring time (

C02593/1

> 0 s)

Feedforward control

C02581/1

: Switching threshold

C02581/2

: Hysteresis for release

C02581/3

: Hysteresis for application

C02593/2

: Application delay

C02593/1

: Actual value monitoring time

C02589/1

: Application time

Œ 

bMBrakeReleaseOut

0

0

bMBrakeReleased

CINH

t

t

t

t

nSpeedSetValue_a_



‘





0

nMotorSpeedAct_a

nSpeedSetValue_a

Œ

Œ Ž

Advertising