8.3

Speed follower

The 8400 StateLine controller only supports the "speed follower" operating mode where the drive

follows a speed setpoint.

8.3.1

Parameter setting

Short overview of parameters for the "speed follower" operating mode:

In the »Engineer», you can set the initial limit by means of the dialog box Min/Max speed.

• Open the Min/max speed dialog box by opening the Application Parameters tab and clicking on

the following button on the dialog level OverviewSignal flow:

Parameter

Info

Lenze setting

Value Unit

C02610/2

MCK: Ramp time synchr. setpoint

2.000 s

C02611/1

MCK: Pos. max. speed

199.99 %

C02611/2

MCK: Pos. min. speed

0.00 %

C02611/3

MCK: Neg. min. speed

0.00 %

C02611/4

MCK: Neg. max. speed

199.99 %