3 speed follower, 1 parameter setting, Speed follower – Lenze 8400 StateLine User Manual
Page 400: Parameter setting, Reques, 8basic drive functions (mck)
8
Basic drive functions (MCK)
8.3
Speed follower
400
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3
Speed follower
The 8400 StateLine controller only supports the "speed follower" operating mode where the drive
follows a speed setpoint.
8.3.1
Parameter setting
Short overview of parameters for the "speed follower" operating mode:
In the »Engineer», you can set the initial limit by means of the dialog box Min/Max speed.
• Open the Min/max speed dialog box by opening the Application Parameters tab and clicking on
the following button on the dialog level Overview Signal flow:
Parameter
Info
Lenze setting
Value Unit
MCK: Ramp time synchr. setpoint
2.000 s
MCK: Pos. max. speed
199.99 %
MCK: Pos. min. speed
0.00 %
MCK: Neg. min. speed
0.00 %
MCK: Neg. max. speed
199.99 %