9diagnostics & error management, 9 error messages of the operating system – Lenze 8400 StateLine User Manual

Page 451

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

451

9

Diagnostics & error management

9.9

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

xx.0123.00094

0x175e

5982

8061022

FC01: Switching frequency reduction

No Reaction

C00590

0x2000

xx.0123.00095

0x175f

5983

8061023

FC02: Maximum speed for Fchop

No Reaction

C00588

0xF000

xx.0123.00099

0x1763

5987

8061027

FC03: Field controller limitation

No Reaction

C00570/4

0xF000

xx.0123.00057

0x1739

5945

8060985

Id1: Motor data identification error

Fault

-

0xF000

xx.0123.00058

0x173a

5946

8060986

Id3: CINH identification

WarningLocked

-

0xF000

xx.0123.00059

0x173b

5947

8060987

Id4: Resistance identification error

Warning

-

0xF000

xx.0123.00074

0x174a

5962

8061002

Id5: Pole position identification error

Fault

C00643/1

xx.0123.00060

0x173c

5948

8060988

Id7: Motor control does not match motor data

Information

C00571/1

0xF000

xx.0123.00061

0x173d

5949

8060989

Id8: Speed sensor has not been set

Fault

C00571/2

0x7120

xx.0123.00145

0x1791

6033

8061073

LP1: Motor phase failure

No Reaction

C00597

0x3000

xx.0123.00015

0x170f

5903

8060943

LU: DC bus undervoltage

Trouble

C00600/1

0x3100

xx.0123.00016

0x1710

5904

8060944

oC1: Power section - short circuit

Fault

-

0x2000

xx.0123.00017

0x1711

5905

8060945

oC2: Power section - earth fault

Fault

-

0x2000

xx.0119.00050

0x1332

4914

7798834

oC5: Ixt overload

Warning

C00604

0x2000

xx.0123.00105

0x1769

5993

8061033

oC6: I2xt motor overload

Warning

C00606

0x2000

xx.0123.00007

0x1707

5895

8060935

oC7: Motor overcurrent

Fault

-

0x2000

xx.0123.00030

0x171e

5918

8060958

oC10: Maximum current reached

No Reaction

C00609

0x2000

xx.0123.00071

0x1747

5959

8060999

oC11: Clamp operation active

Fault

-

0xF000

xx.0123.00065

0x1741

5953

8060993

oC12: I2xt brake resistor overload

Fault

-

0xF000

xx.0123.00090

0x175a

5978

8061018

oC13: Maximum current for Fch exceeded

Fault

-

0xF000

xx.0123.00096

0x1760

5984

8061024

oC14: Direct-axis current controller limitation

No Reaction

C00570/1

0xF000

xx.0123.00097

0x1761

5985

8061025

oC15: Cross current controller limitation

No Reaction

C00570/2

0xF000

xx.0123.00098

0x1762

5986

8061026

oC16: Torque controller limitation

No Reaction

C00570/3

0xF000

xx.0123.00031

0x171f

5919

8060959

oC17: Clamp sets pulse inhibit

No Reaction

C00569/1

0xF000

xx.0119.00001

0x1301

4865

7798785

oH1: Heatsink overtemperature

Fault

-

0x4000

xx.0119.00015

0x130f

4879

7798799

oH3: Motor temperature (X106) triggered

Fault

C00585

0x4000

xx.0119.00000

0x1300

4864

7798784

oH4: Heatsink temp. > shutdown temp. -5°C

No Reaction

C00582

0x4000

xx.0123.00032

0x1720

5920

8060960

oS1: Maximum speed limit reached

No Reaction

C00579

0x8400

xx.0123.00033

0x1721

5921

8060961

oS2: Max. motor speed

Fault

-

0x8400

xx.0123.00001

0x1701

5889

8060929

ot1: Max. torque reached

No Reaction

C00608

0x8300

xx.0123.00093

0x175d

5981

8061021

ot2: Speed controller output limited

No Reaction

C00567

0xF000

xx.0123.00014

0x170e

5902

8060942

OU: DC bus overvoltage

Trouble

-

0x3100

xx.0144.00001

0x2c01

11265

9437185

PS01: No memory module

Warning

-

0x6300

xx.0144.00002

0x2c02

11266

9437186

PS02: Invalid par. set

Fault

-

0x6300

xx.0144.00003

0x2c03

11267

9437187

PS03: Invalid device par. set

Fault

-

0x6300

xx.0144.00004

0x2c04

11268

9437188

PS04: Invalid MCI par. set

Fault

-

0x6300

xx.0144.00007

0x2c07

11271

9437191

PS07: Invalid memory module par. set

Fault

-

0x6300

xx.0144.00008

0x2c08

11272

9437192

PS08: Invalid device par.

Fault

-

0x6300

xx.0144.00009

0x2c09

11273

9437193

PS09: Invalid par. format

Fault

-

0x6300

xx.0144.00010

0x2c0a

11274

9437194

PS10: Memory module binding invalid

Fault

-

xx.0123.00205

0x17cd

6093

8061133

Sd3: Feedback system open circuit

Fault

C00586

0x7300

xx.0123.00200

0x17c8

6088

8061128

Sd10: Speed limit for feedback system 12

Fault

C00607

0x7300

xx.0111.00002

0x0b02

2818

7274498

Su02: One mains phase is missing

Warning

C00565

0x3000

xx.0111.00003

0x0b03

2819

7274499

Su03: Too frequent mains switching

Fault

-

0x3000

xx.0111.00004

0x0b04

2820

7274500

Su04: CU Insufficiently Supplied

Warning

-

0x3000

xx.0111.00006

0x0b06

2822

7274502

Su06: Mains input overload

Fault

-

0x3000

Error number

Display in

Error message

Response

(Lenze setting)

can be set in CAN

Emergency

Error Code

32 bits

16 bits

hex

16 bits

dec

C00162/1