17

Function library

17.1

Function blocks

980

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.40

L_PT1_1

This FB filters and delays analog signals.

• The filter time constant T can be set under

C00249

.

• The gain is defined with V

p

= 1.

Inputs

Outputs

Parameter

Function

[17-22] Filter time constant T of the first-order delay element

Identifier

Data type

Information/possible settings

nIn_a

INT

Input signal

Identifier

Data type

Value/meaning

nOut

INT

Output signal

Parameter

Possible settings

Info

C00249

0

ms

5000 Filter time constant

• The filter is not active with a

setting of "0 ms". The input signal

is passed through one-to-one to

the output.

• Lenze setting: 2000 ms

/B37B

)LOWHUWLPH

&

Q,QBD

Q2XWBD

T

V = 1

p

t