Oc6: i2xt motor overload, Oc6: i2xt overload motor, Error message – Lenze 8400 StateLine User Manual

Page 461: Lp1: motor phase failure, Sd3: open circuit - feedback system, Xx.0125.00001, Xx.0123.00145, Xx.0123.00105, Xx.0123.00205, Xx.0123.00200

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

461

9

Diagnostics & error management

9.9

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

oC6: I2xt overload - motor [xx.0123.00105]

LP1: Motor phase failure [xx.0123.00145]

Sd10: Speed limit - feedback system 12 [xx.0123.00200]

Sd3: Open circuit - feedback system [xx.0123.00205]

An01: AIN1_I < 4 mA [xx.0125.00001]

Response (Lenze setting printed in bold)

Setting:

C00606

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Thermal overload of the motor.

Only self-ventilated motors can be monitored using the

I2xt function.

• Check whether is it a self-ventilated motor. If not, set

C00606

to "0: No Reaction".

• Observe load requirements.

• Correct dimensioning if necessary.

• For VFCplus control type: Check Vmin boost (

C00016

).

Set Vmin boost

Response (Lenze setting printed in bold)

Setting:

C00597

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Motor phase failure - power section

• This error message is displayed if a motor phase

carries less current of one half-wave than set in

C00599

.

• Check the motor connections and the corresponding

plug connector on the device and, if necessary, the

motor terminal box.

• Check the trigger threshold (

C00599

).

Response (Lenze setting printed in bold)

Setting:

C00607

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Maximally permissible speed of the feedback system

connected to DI1/DI2 reached.

Reduce speed of the rotation shaft/feedback system.

n

encoder

<= (f

max

x 60) / encoder increments

(for f

max

= 10 kHz)

Response (Lenze setting printed in bold)

Setting:

C00586

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

• HTL encoder cable interrupted.

• HTL encoder is defective.

Note: May also be caused by a very dynamic acceleration

or starting up against a blocked motor shaft (e.g. with a

closed holding brake).

• Check HTL encoder cable.

• Check HTL encoder.

• Check related terminals.

• Switch off monitoring (

C00586

= "0: No reaction")

when the HTL encoder is not used.

Response (Lenze setting printed in bold)

Setting:

C00598/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Open-circuit monitoring for analog input 1 has tripped.

• Only if the analog input has been configured as a

current loop of 4 ... 20 mA (

C00034/1

= 2).

• Check wiring of the analog X3/A1I input terminal for

open circuit.

• Check minimum current values of the signal sources.

Advertising