C00594 | resp. to control word error, C00595 | mck: resp. to mck error, C00594/1 – Lenze 8400 StateLine User Manual

Page 710: C00594/2, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00594

710

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00594

C00595

Parameter | Name:

C00594 | Resp. to control word error

Data type: UNSIGNED_8

Index: 23981

d

= 5DAD

h

Configuration of device control monitoring
Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
5 Warning

Subcodes

Lenze setting

Info

C00594/1

1: Fault

Response if error bit 14 in the CAN control word is set.

C00594/2

1: Fault

Response if error bit 14 in the MCI control word is set.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00595 | MCK: Resp. to MCK error

Data type: UNSIGNED_8

Index: 23980

d

= 5DAC

h

Configuration of monitoring of the Motion Control Kernel

Basic drive functions

Selection list

0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C00595/1

0: No Reaction

Reserved

C00595/2

0: No Reaction

Reserved

C00595/3

0: No Reaction

Reserved

C00595/4

0: No Reaction

Reserved

C00595/5

0: No Reaction

Reserved

C00595/6

0: No Reaction

Reserved

C00595/7

0: No Reaction

Reserved

C00595/8

0: No Reaction

Reserved

C00595/9

0: No Reaction

Reserved

C00595/10

0: No Reaction

Reserved

C00595/11

0: No Reaction

Reserved

C00595/12

0: No Reaction

Reserved

C00595/13

0: No Reaction

Reserved

C00595/14

0: No Reaction

Reserved

C00595/15

1: Fault

Response to activated connection monitoring in case of

PC manual control

From version 11.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1