Step 7. Secure the panel to the CobraNet interface

module slot section with 2 screws.
Ensure that 2 connectors of the D-2000CB
project from the rectangle hole in the panel
before tightening screws.

[Installing the input, output, and control modules]

After mounting completion of the D-2000CB, install
other modules with the removed screws that held the
blank panels.
Further, replace the removed blank panels to the idle
slots.

D-2008SP

D-2000CB

D-2000CB's connector

Panel
(removed in step 4)

7

Machine screw M3 x 8
(removed in step 4)

Terminal pins of the connector are exposed on the solder side of
the D-2000CB board. Never touch these terminal pins when
inserting the connector to prevent finger injury.

CAUTION

Step 6. Secure the D-2000CB to the inside of the D-2008SP with 1 screw.

Note
Be sure to secure the D-2000CB with the screw.
Doing otherwise may cause its connector to be disconnected, resulting in malfunction.

Step 4. Remove the D-2000CB's panel.

Note: The removed 2 screws are used in step 7.

Step 5. Insert the D-2000CB's connector into the D-2008SP's internal connector.