D-984vc specifications, Control input terminals] [control output terminals – Toa D-2000 Series Installation User Manual

Page 39

Advertising
background image

39

4.8. D-984VC Specifications

The optional VCA Fader Unit D-911 can remotely control the VCA Control Module D-984VC.
However, You can make a special unit having the same functions as the D-911 referring to the technical
information described here.

4.8.1. Connection cable and pin arrangements of each terminal

• For connecting to each terminal, use a CAT5 (Category 5) UTP cable fitted with RJ45 connectors at both

ends.
Note
Use a STP cable in an environment where the cable is susceptible to noises.

• Maximum cable length is 100 m.
• Pin arrangement of the D-984VC's terminals

model D-984VC

VCA

CONTROL

MODULE

CONTROL

UNITS FOR D-901 ONL

Y

1-4
5-8

1-6

7-12

1-4
5-8

1-4
5-8

CTRL IN

IN CH

CTRL OUT

OUT CH

VCA

Input channel
VCA terminals

Output channel
VCA terminals

Control input
terminals

D-984VC

Control output
terminals

Pin No.

1
2
3
4
5
6
7
8

1 – 6

IN CH 1
IN CH 2
IN CH 3
IN CH 6
IN CH 5
IN CH 4

V
C

7 – 12

IN CH

IN CH 7
IN CH 8
IN CH 9

IN CH 12

IN CH 11

IN CH 10

V
C

Pin No.

1
2
3
4
5
6
7
8

1 – 4

OUT CH 1
OUT CH 2
OUT CH 3

C
V

OUT CH 4

V
C

5 – 8

OUT CH

OUT CH 5
OUT CH 6
OUT CH 7

C
V

OUT CH 8

V
C

[Input channel VCA terminals]

[Output channel VCA terminals]

Pin No.

1
2
3
4
5
6
7
8

1 – 4

CTRL IN 1

C

CTRL IN 2

C

CTRL IN 3

C

CTRL IN 4

V

5 – 8

CTRL IN

CTRL IN 5

C

CTRL IN 6

C

CTRL IN 7

C

CTRL IN 8

V

Pin No.

1
2
3
4
5
6
7
8

1 – 4

CTRL OUT 1

C 1

CTRL OUT 2

C 3

CTRL OUT 3

C 2

CTRL OUT 4

C 4

5 – 8

CTRL OUT

CTRL OUT 5

C 5

CTRL OUT 6

C 7

CTRL OUT 7

C 6

CTRL OUT 8

C 8

[Control input terminals]

[Control output terminals]

1

2

3

4

5

6

7

8

4.8.2. Input and output channel VCA controls (1) – (4)

• With 5 V at an input channel VCA pin (IN CH 1 – 12) or at an output channel VCA pin (OUT CH1 – 8), the

corresponding channel's sound volume is minimum. With 0 V, the sound volume is at the level set by the D-
2008SP.

• Use 10 kΩ potentiometers of taper B.
• Up to 6 volume controls can be connected to each V pin.

[Connections to the input channel VCA terminal]

1 IN CH 1

RJ45

D-984VC
[IN CH 1 – 6]

2 IN CH 2
3 IN CH 3
4 IN CH 6
5 IN CH 5
6 IN CH 4
7 V (+5 V)
8 C (GND)

D-2008SP's volume

Minimum level

+5 V

0 V

Advertising
This manual is related to the following products: