4.10.2. Redundant configuration of switching hubs

In the connection example below, the CobraNet PRIMARY and SECONDARY terminals of each unit are
individually connected to different switching hubs. Even if any one of the switching hubs fails or Main line
breaks, the system is kept operating using another Main line, thus preventing system down.

Notes
• Cycle the entire system's power after connection completion.
• Perform spanning tree setting within switching hubs. For the settings, refer to the instruction manual of the

switching hub.

• Audio signals may be interrupted temporarily at the time when the network configuration automatically

changes due to failure of any switching hub or disconnection of the main line.

• Contact your TOA dealer for more information on switching hubs.

D-2008SP

D-2008SP

D-2008SP

D-2008SP

Switching hub

(SECONDARY-1)

Switching hub

(SECONDARY-2)

Switching hub

(PRIMARY-2)

Switching hub

(PRIMARY-1)

To other
switching hub

To other
switching hub

To other
switching hub

To other
switching hub

CobraNet unit

Main line

Main line

Main line

Category 5 or higher shielded
twisted pair cable for LAN
(with RJ45 connectors)

PRIMARY

SECONDARY

PRIMARY

SECONDARY

PRIMARY

SECONDARY

PRIMARY

SECONDARY

PRIMARY

SECONDARY