Dataman 48Pro User Manual

Page 53

Advertising
background image

Software

socket (continuity test). The programmer is able to
identify the wrong contact, misinserted chip and also
(partially) backinserted chip.

check ID bytes

(default

ENABLE)

If enabled, the programmer checks the electronic ID of
the programmed chip.
Note 1: Some old chips don't carry electronic ID.
Note 2: In some special cases, several microcontrollers
don't provide ID, if copy protection feature in the chip is
set, even if device ID check setting in control program is
set to "Enable".


group Command execution:

blank check before programming

(default DISABLE)

erase before programming (default

DISABLE)

verify after reading (default

ENABLE)

verify

(ONCE, TWICE)

verify

options

(nominal VCC +/-5%

nominal VCC +/-10%
VCCmin - VCCmax)


group ISP Target Supply Parameters

Enable target system power supply - enables supplying of
target system from programmer. Supply voltage for target
system is switched on before action with programmed device
and is switched off after action finished. If Keep ISP signals
at defined level after operation is enabled, then programmer
will switch off supply voltage after pull-up/pull-down resistors
are deactivated.

Voltage - supply voltage for target system.

Max. current - maximum current consumption of powered
target system.

Voltage rise time - determines skew rate of rising edge of
target supply voltage (switch on supply voltage).

Target supply settle time - determines time, after which
must be supply voltage in target system stabilized at set
value and target system is ready to any action with
programmed device.

Voltage fall time - determines skew rate of falling edge of
target supply voltage (switch off supply voltage).

Power down time - determines time after switch off target
system power supply within target system keeps residual
supply voltage (e.g. from charged capacitor). After this time

53