Device / read, Device / verify, Device / program – Dataman 48Pro User Manual

Page 66: Device / erase, Device / test, Device / ic test

Advertising
background image


Device / Read

This command allows reading the entire device or part of it into
the buffer. The control program displays a message in the
INFO window when finished.

The menu command Device / Device options / Operation
options
allows the setting of parameters related to the read
device operation. Setting the option Verify data after reading in
this menu command means a higher reliability for device
reading.

Device / Verify

This command compares the programmed data of the device
with the data in the buffer. The control program displays the
result of this action by a message to the INFO window.

The menu command Device / Device options / Operation
options
allows the setting of parameters related to the verify
device operation.

In the menu Options / Display errors, the errors can be
displayed on the screen, written to the file: VERIFY.ERR or
disabled.

Device / Program

This command allows the programming of the device or part of
it by the data in the buffer. The control program displays the
result of this action by a message to the INFO window.

The menu command Device / Device options / Operation
options
allows the setting of parameters related to the
program device operation.

Device / Erase

This command allows erasing of the entire programmable
device. The control program displays the result of this action by
a message to the INFO window.

Device / Test

This command executes a test on the selected device selected
from list of supported devices (e.g. static RAM) on
programmers, which support this test.

Device / IC test

This command activates a test section for ICs separated by
type to any libraries (on distribution CD). First select an

66

Advertising