Hydraulic seed meter calibration numbers – Ag Leader InSight Ver.8.0 Users Manual User Manual

Page 125

Advertising
background image

111

P

LANTING

Hydraulic Seed Meter Calibration Numbers

Prior to calibrating the Hydraulic Seed Meter, the numbers that appear in the Meter Calibration box in the
Planter Control window should be similar to the numbers that appear below. If they are not, then your
seed meter may be working incorrectly, or you may have set the Gear Ratio incorrectly. In these cases,
contact Ag Leader Technical Support for further assistance.

Note: Check your operator’s manual for more specific information on other seed disk options.

Planter Brand and Type

Corn

Soybeans

Cotton

Standard

Rate

Sorghum

John Deere

Vacuum: Standard

30

108

64

45

Vacuum: ProMax™

40

Vacuum: Precision Planting

eSet®

30

Vacuum: VenHuizen AccuVac

Kit

40

Mechanical: Finger

12

Mechanical: Brush Meter

56

Case IH

Vacuum

48

60

80

80

Cyclo®

36

240

White

30

60

KINZE

EdgeVac®

39

60

54

60

Mechanical: Finger

12

56

48

60

Advertising