New controller product notes – Ag Leader InSight Ver.8.0 Users Manual User Manual

Page 195

Advertising
background image

181

A

PPLICATION

1. Select Controller or Flow Meter

Select the controller type from the Device list box. For all
selections other than Serial Controller a second list box will
be present requiring choice of liquid or granular product
control.

If setting up a serial controller, press NEXT.

If setting up a liquid DirectCommand controller or flow meter
logging system, press NEXT and continue with Step 3.

If setting up a granular DirectCommand controller, continue
with Step 3.

2. Select Serial Controller Make and Model

If you selected Serial Controller in the previous step, you should now enter the Serial Controller make
and model from the appropriate list boxes and press NEXT. Continue at

“Finish Controller Setup” on

page

181

.

3. Enter Calibration Number

Enter the Flow Meter calibration number using the Number Pad. Press NEXT to continue.

Note: For individual product information, see

“New Controller Product Notes” on page

181

4. Finish Controller Setup

Edit controller name if desired and press FINISH to complete the process of configuring a new controller.

New Controller Product Notes

As you add a new controller, keep in mind the following regarding these application products.

• Raven
Raven flow meter tags represent pulses per 10 gallons. Divide the calibration number by 10 before entering
into the display. For more information, see

“Controller Settings: Direct Injection Pump Calibration” on

page

269

.

• Tee Jet
Tee Jet meter calibration numbers represent pulses per liter. To convert the number, multiply the value
found on the flow meter by 3.79 to find the pulses per gallon needed for the display.

• Mid-Tech
Mid-Tech flow meters sometimes have a cable with a module. The calibration number found on this cable
is in pulses per gallon/divided by 16. The display should bypass this module and plug directly into the flow
meter. If that is the case then multiply the calibration number by 16 before entering it into the display.

Advertising