Create an optrx v.i. reference value, Scan a reference strip, Recording a reference value – Ag Leader InSight Ver.8.0 Users Manual User Manual
Page 244: Scan a reference strip recording a reference value, V.i. r
230
12. Select Controller
Use the drop-down menu to select a controller, or press the New button to add a controller; then press
NEXT.
13. Select Container
Use the drop-down menu to select a container, or press the New button to enter a new container; then
press NEXT to continue.
14. Enter Container Capacity and Units
The Container Setup Wizard appears. Use the numeric keypad to enter the container capacity and the
drop-down menu, located underneath, to enter units. Press NEXT to continue.
15. Select Container Name and Location
Use the keypad to enter a Container Name, and the drop-down menu underneath to enter a Container
Location.
16. Select Ground Speed Source
Select your ground speed source. If you will be using GPS as the primary you will need to select a
secondary source.
Press NEXT to continue.
Note: The Ground Speed Sensor must be calibrated for accurate speed and area calculations, under the
Vehicle Tab.
17. Enter Suggested Configuration Name
Use the keypad to enter a suggested name for your configuration.
Press Finish when complete.
Note: A suggested name has been provided, based on your previous selections. If this name does not fully
describe the configuration, you may change it here.
C
REATE AN
O
PT
R
X
V.I. R
EFERENCE
V
ALUE
In order for the OptRx Crop Sensor Module to recommend an N rate, you must scan the field to find a
V.I. Reference Value. To find a Reference Value, choose the healthiest portion of your field where the
tallest and greenest plants are located, and scan this portion for 300 seconds (5 minutes). This V.I.
Reference Value is a baseline of optimum crop performance that the display can compare against other
cropland.
Scan a Reference Strip
This procedure describes how to scan a reference strip into the display. It assumes that you have
already performed the following tasks:
• Identified that your crop is at the appropriate growth stage.
• Created an OptRx module configuration. For more information, see
“OptRx Crop Sensor Configuration” on
• Created a Grower, Farm and Field configurations at the Run screen.
Recording a Reference Value
1. Press Create Button
Press the Create button, located underneath the Reference
Strip indicator on the Crop Settings tab of the Run screen.