Spinner spreader static conveyor calibration, Spinner spreader static, And also – Ag Leader InSight Ver.8.0 Users Manual User Manual

Page 251

Advertising
background image

237

A

PPLICATION

Spinner Spreader Static Conveyor Calibration

Because the Spinner Speed settings can only be accurately determined by performing a spread pattern
catch test, you must perform a conveyor discharge calibration for each granular product control channel
(bin) for the equipment configuration. This process is outlined on the following pages. The static
calibration procedure is performed before applying in field conditions.

To begin, press the Spreader Control button on the Run screen. The Spreader Control window
appears, as shown in Step 1 below.

1. Start Calibrate Conveyor routine

Press Static Calibration to start the Static Conveyor Rate
calibration routine.

2. Disable Spinner Hydraulic Circuit

The display will present a warning to disable the spinner
hydraulic circuit.

Press OK to continue after the hydraulic circuit is disabled.

WARNING: Manually disable or shut off the spinner hydraulic circuit. If the spinner runs unexpectedly, injury
could occur.

3. Select Conveyor to Calibrate

Press NEXT to continue.

4. Enter Dispense Amount

Enter the desired target amount of product to dispense (the recommended amount is 500 pounds or 250
kilograms).

Press NEXT to continue.

5. Start Dispensing Product

Press Start to begin dispensing the product.

6. Product Dispensing

The conveyor will stop when the display perceives the target amount of product has been dispensed.

The Stop button can be pressed at any time to manually shut off the conveyor.

7. Product Dispensing Stops

Next appears the window after dispensing the display’s target amount.

This value can be reset and the process started again for a larger sample size, if desired.

Press NEXT to continue.

8. Enter Actual Dispense Amount

Enter the actual weight of the product dispensed.

Press NEXT to continue.

9. Finish Calibration

At left is displayed the window showing the new calibration number.

• Press Cancel to exit calibration without saving the value.

Advertising