GPI Input Setting (GPI Input Assign Menu)

state of the cross-point is restored. If the GPI trigger is applied repeatedly at
short intervals (0.5 second or less), the cross-point switching may not be
carried out correctly. In this case, apply the GPI trigger again.

• If “SWR Format” or “System Format” is selected for “Action” when the

format converter is used, you can set the conversion formats of the format
converter for “FC Input 1-8.”

Carrying out level settings

To set the low level and high level, first set the trigger type to “Level,” then use
the following procedure.

1

In the DCU >GPI Input Assign menu, select the action to be set, and press
[H/L Set].

The H/L Set menu appears.

2

Using any of the following methods, select the settings.

• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.

3

To apply the selection made in step

2

when the input is the GPI high level,

press [H Set]. To apply the selection made in step

2

when the input is low,

press [L Set].

This confirms the setting, which appears in the status area.

Knob

Parameter

Adjustment

Setting values

1