DME

Chapt

er

11

DME Ope

ra

tions

Resetting of parameter values set in the source coordinate space

In some transformation operation modes, if you switch to the target coordinate
space after setting up a three-dimensional transformation in the source
coordinate space, the setting values in the source coordinate space (three-
dimensional parameter values) are converted to values in the target coordinate
space (source/target conversion).
Once a conversion has taken place, the original source coordinate space
parameters do not return to their original values when you switch back to the
source coordinate space. They are reset to zeros.
Source/target conversion occurs in the following operation modes:
• Location XYZ
• Rotation

Transformation Operation Modes

The following operation modes are available for three-dimensional DME
transformations. These operations are carried out in the device control block
(trackball or joystick). (

For details, see “Three-Dimensional Transformation

Operations” (page 424).)

Location XYZ

Moves the image on the x-axis, y-axis, or z-axis. The direction of movement
differs depending on whether you are manipulating the image in the source
coordinate space or the target coordinate space.

Image movement in the source coordinate space

Movement on the x-axis

Movement on the y-axis

Movement on the z-axis