Testing trigger output, Clearing output port settings, Setting the action for a rewind operation – Sony Multi Interface Shoe Adapter User Manual

Page 588

Advertising
background image

588

Control of GPI Devices

Ch
apt

er 12

Ex
te

rn

al De

v

ic

e

s

5

Press [Set].

This specifies the SCU/DCU GPI port whose number you specified in step

4

as the pulse output destination for the GPI output port selected in the list

on the left of the status area.

Repeat steps

1

to

5

for other GPI output ports as required.

Testing trigger output

To test the trigger output, press [Test Fire].
According to the list settings on the left of the status area, a pulse is output from
the selected output port.

Clearing output port settings

To clear the settings for each device (GPI output port)

1

In the list on the left of the status area, select the GPI output port whose
settings you want to clear.

2

In the list on the right, select “Off.”

3

Press [Set].

To clear the settings for all devices (GPI output ports) in a single
operation

Press [All Off].

Setting the action for a rewind operation

On the GPI timeline, when the [REWIND] button in the keyframe control
block is pressed the action set for the first keyframe is not executed; when the
[RUN] button is pressed, then the first keyframe action is executed.
To execute an action when the [REWIND] button is pressed, it is necessary to
set this action (Rewind Action). To carry out this setting, in the Device >GPI
Timeline menu, press [Rewind Action] to recall the Rewind Action menu. In
this setting screen, use the same setting method as in the screen for setting an
action on the GPI timeline.

Alternatively, you can select the reverse arrangement, whereby when the
[REWIND] button is pressed, this executes the action set for the first keyframe,
and when the [RUN] button is pressed the first keyframe action is not executed.
In this case, the Rewind Action setting is still valid.