Di/do diagram – Vivotek SD9161-H-v2 2MP PTZ Network Dome Camera User Manual

Page 12

Advertising
background image

VIVOTEK

12 - User's Manual

DI/DO Diagram

DI-

DO+

DI+

DO-

Switch

External Device

External DC power

Dry contact with external DC power source to supply a relay. Dry contact is the safest connec

ti

on

to protect devices.

NC

NO

Relay

Photo

Coupler

DC

DC 0V

DC 0V

External AC power

with Protected Earth

AC

PE

PE

DI-

DO+

DI+

DO-

Switch

External Device

External DC power

Wet contact with external DC power source to supply a relay.

NC

NO

Relay

DC

External AC power

with Protected Earth

AC

PE

PE

DC 0V

1. The max. voltage for DO- pins is 30VDC (External power).

In order to control AC devices, the above diagram can be taken in consideration. The diagram

uses a relay to control the ON/OFF condition of the AC device.

2. An external relay can be triggered by using DO+ or by an external power source, depending

on the type of relay you use.

3. In case of using an individual relay (instead of using a relay module), for protection against

voltage or current spikes, a transient voltage suppression diode must be connected in parallel

with the inductive load.

Advertising