PARAMETER

VALUE

SECURITY
(get/set)

DESCRIPTION

name

string[40]

6/6

Identification of this entry.

ipaddress

<ip address>

6/6

The ipaddress of the receiving camera.

username

string[64]

6/6

The username of the receiving camera.

passwd

string[64]

7/6

The password of the receiving camera.

port

0~65535

6/6

The connection port to the receiving
camera.

do

<integer>[trigger
time]

6/6

Indicate the source id and trigger time of
di trigger.
Ex. “0[10]” sets do0 with trigger time of
10 s for the receiving camera.

autotrack_enable

<Boolean>

6/6

Enables autotracking for the receiving
camera.

autotrack_index

0,<positive
integer>

6/6

PTZ preset index with smart tracking
advanced of the receiving camera.

* Only valid when the camera supports
“Smart Tracking Advanced” feature.
(Please refer to PTZ Control API for more
details)

* We support this parameter when the
version number (httpversion) is equal or
greater than 0317d.

gotopreset_enable

<Boolean>

6/6

Enable the PTZ preset function of the
receiving camera.

gotopreset_type

mechanical, digital 6/6

PTZ type of the receiving camera.

gotopreset_index

0, <positive
integer>

6/6

PTZ preset index of the receiving camera.

gotopreset_channel

0, <positive
integer>

6/6

PTZ preset channel of the receiving
camera.

gotopreset_stream

0, <positive
integer>

6/6

PTZ preset stream of the receiving
camera.