1.3 Technical

Specifications

Table 1. CT-7000 S3 Technical Specifications

TYPE Portable circuit-breaker analyzer

PHYSICAL SPECIFICATIONS 14”W x 21 K” L x 8” D (35 cm x 53 cm x 20 cm); 15 lbs (6.8 Kg)

INPUT POWER

100-240Vac, 3A, 50/60Hz

DRY-CONTACT INPUTS 3 channels (9021-UC) or 6 channels (9100-UC). Channel can detect the main contact

and resistor contact time.

TIMING WINDOWS 1 second, 10 seconds, or 20 seconds

TIMING RESOLUTIONS ±50 micro-seconds @ 1 sec. duration

±500 micro-seconds @ 10 sec. duration
±1.0 milli-seconds @ 20 sec. duration

TIMING ACCURACY 0.05% of reading ±0.05 ms @ 1 second duration

DRY-CONTACT CHANNEL PROTECTION All contact inputs are grounded until test. Input channels are also protected against

static discharge.

DRY-CONTACT DETECTION RANGE Closed: Less than 20 Ohm.

Opened: greater than 5000 ohm

INSERTION RESISTOR DETECTION

RANGE

50 – 5,000 ohms

TRIGGER INPUT VOLTAGE Open/Close trigger voltage: 24 V – 300V DC or peak AC

VOLTAGE SENSING INPUT RANGE V1: analog input; 0 – 250 V DC or peak AC; sensitivity ±1 V; record and print voltage

level
V2 and V3: voltage presence/absence detector input; 24 – 255 V DC or peak AC;
record and print 3 timing events

BREAKER OPERATIONS

Initiate Open, Close, Open-Close, Close-Open, Open-Close-Open

BREAKER INITIATE CAPACITY 30A, 250 Vac/dc max

INITIATE CURRENT READING RANGE one, non-contact, Hall-effect sensor, 0 – 20 amp range, dc to 5 Khz AC

DIGITAL TRAVEL TRANSDUCER

INPUTS

3 digital travel transducer channels; linear range: 0.0 – 60.0 in (±0.01 in)
rotary range: 0 – 360 degrees (±0.36 degrees)

RESISTOR TYPE TRANSDUCER INPUTS 3 channels, 200 ohms – 10K ohms

CONTACT TRAVEL POINT DIFFERENCE measures “slow-close” contact-point distances; results can be printed

DISPLAY back-lit LCD screen (128 x 240 pixels); viewable in bright sunlight and low light

PRINTER

built-in 4.5” wide thermal printer that can print both graphic contact travel waveforms
and tabulated test results

INTERNAL TEST RECORD STORAGE Store up to 200 test records and 100 test plans

EXTERNAL TEST RECORD STORAGE USB Flash drive interface for external storage of test records (999 max) and test plans

COMPUTER INTERFACES One USB port, optional Bluetooth wireless interface

PC SOFTWARE Windows® based Breaker Analysis software included with purchase price

CABLES furnished with full set of test leads

OPTIONS transportation cases (available for the CT-7000 S3 and travel transducers), on-line

timing mode, dual ground testing mode, bluetooth interface

SAFETY

designed to meet UL 6101A-1 and CAN/CSA C22.2 No 1010.1-92 standards

ENVIRONMENT

Operating: -10°C to +50°C (+15°F to +122°F)
Storage: -30°C to +70°C (-22°F to +158°F)

HUMIDITY

90% RH @ 40°C (104°F) non-condensing

ALTITUDE 2,000 m (6,562 ft) to full safety specifications

WARRANTY one year on parts and labor

NOTE

The above specifications are valid at nominal operating voltage and at a
temperature of 25

°C (77°F). Specifications may change without prior notice.