Vanguard CT-7000 S3 User Manual
Page 61
REV 1 CT-7000 S3 USER’S MANUAL
56
g. The following screen will be displayed:
1. Contact #1 CLOSE
Press the
[1]
key if you would like the open operation to be initiated after contact
channel #1 is closed. Continue to step h.
2. Set DELAY
Press the
[2]
key to set a delay time between the CLOSE command and the OPEN
command. The following screen will be displayed:
Type the delay time using the keypad and then press the
[ENTER]
key. Continue
to step h.
3. No DELAY
Press the
[3]
key to initiate the CLOSE and OPEN commands simultaneously.
Continue to step g.
h. The following screen will be displayed:
Hold down the
[ARM]
switch and press the
[START]
key.
HOLD "ARM" UNTIL
TEsT COMPLETES.
"START" TO BEGIN
"STOP" TO ABORT
C-O DELAY IN MS:
(10 - 500)
MSEC
"ENTER" WHEN DONE
C-O SECOND TRIGGER:
1. CONTACT #1 CLOSE
2. SET DELAY
3. NO DELAY