Timers

16-Bit Timer Setup Examples

MN102H75K/F75K/85K/F85K LSI User Manual

Panasonic Semiconductor Development Company

107

Panasonic

change any other operating modes during this step.

When TM4MD[1:0] = b’10’ (dur-

ing capture), TM4CA and
TM4CB become read-only regis-

ters. To write to TM4CA or

TM4CB, you must first set
TM4MD[1:0] = b’00’.

3.

Set TM4NLD and TM4EN to 1. This starts the timer. Counting begins at the
start of the next cycle.

To enable timer 4 capture B interrupts:

Cancel all existing interrupt requests. Next, set the interrupt priority level in the
TM4CBLV[2:0] bits of the TM4CBICH register (levels 0 to 6), set the TM4BIE

bit to 1, and set the TM4BIR bit of TM4CBICL to 0. From this point on, an
interrupt request is generated whenever a timer 4 capture B event occurs.

To service the interrupts and calculate the signal width:

1.

Run the interrupt service routine. The routine must determine the interrupt

group, then clear the interrupt request flag.

Ignore the flags when calculat-

ing the signal width, even when

TM3CA is the larger value.

2.

Calculate the number of cycles the TM4IA signal stays high. Save the con-

tents of TM4CA and TM4CB to the data registers, then subtract the contents
of TM4CA from the contents of TM4CB. Since TM4LP is set to 0, the dif-

ference will be the correct value even if TM4CA is greater than TM4CB.

Timer 4 can input a single-phase capture signal. You must select up counting.

Timer 4 does not operate in STOP mode, when B

OSC

is off. If you use an external

clock, it must be synchronized to B

OSC

.

TM4CA captures the count on the rising edge of TM4IA, and TM4CB captures
the count on the falling edge of TM4IA. A timer 4 capture B interrupt occurs

when TM4CB captures the count, and the contents of TM4CA and TM4CB are
read during the interrupt service routine.

In the example timing chart shown in figure 4-36, x’000A’ – x’0007’ = x’0003’,
or 3 cycles. The calculation is correct even when TM4CA is the larger value. The

flags are ignored, so for instance, x’0003’ – x’FFFE’ = x’0005’.

Figure 4-36 Single-Phase Capture Input Timing (Timer 4)

TM4EN

TM4BC

B

OSC

/4

TM4CA

TM4CB

TM4IA

Interrupt

0

1

2

3

4

0

5

6

7

8

9

A

B

C

D

E

F 10 11 12

0

7

0

A

A-7=3

B