background image

Timers

16-Bit Timer Setup Examples

Panasonic Semiconductor Development Company

MN102H75K/F75K/85K/F85K LSI User Manual

116

Panasonic

To service the interrupts:

Run the interrupt service routine. The routine must determine the interrupt group,

then clear the interrupt request flag.

Timer 5 can input a two-phase encoder signal. Timer 5 does not operate in STOP

mode, when B

OSC

is off. If you use an external clock, it must be synchronized to

B

OSC

.

Table 4-5 shows the count direction for the timing diagram in figure 4-46. In
down counting, when the binary counter reaches 0, it loops to the value in

TM5CA. An interrupt B occurs when the contents of TM5BC match those of
TM5CB.

Table 4-5 Count Direction for 1x Two-Phase Encoder Timing Example

Up Counting

Down Counting

TM5IA

TM5IB

1

1

Figure 4-46 1x Two-Phase Encoder Input Timing (Timer 5)

TM5CA

TM5CB

TM5BC

TM5IA

TM5IB

Interrupts

0000

1FFF

1FFE

1FFD

1FFE

1FFF

1FFF

0000

0001

0FFF

1000

1000

1001

B

A