All registers in RMC block cannot be written by byte (by word only). Read by

byte is possible.

RMIR: Remote Signal Interrupt Control Register

x’007EA2’

RMIR controls the operating modes and interrupt operations for the
receiver circuit. It is a 16-bit access register.

MODAUTO: Automatic operating mode detection on/off

0: Automatic detect
1: Fixed

MODSEL: Operating mode select

0: HEAMA format

1: 5-/6-bit format

FILTRE: Noise filter input multiplexer on/off

0: Pin level
1: Noise filter

POLSEL: Input polarity

0: Positive-edge-triggered
1: Negative-edge-triggered

LEADERE: Interrupt enable for leader detection

0: Disable

1: Enable

TRAILRE: Interrupt enable for trailer detection

0: Disable
1: Enable

DAT8E: Interrupt enable for 8-bit data reception detection

0: Disable
1: Enable

EDMEE: Interrupt enable for RMIN pin edge detection

0: Disable

1: Enable

Bit:

7

6

5

4

3

2

1

0

MOD

AUTO

MOD

SEL

FILTR

E

POL

SEL

LEADER

E

TRAILR

E

DAT8

E

EDME

E

Reset:

0

0

0

0

0

0

0

0

R/W:

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W