Conventions, Command structure, Appendix e: serial commands – ClearOne XAP 800 User Manual

Page 100: Appendices ~ appendix e: serial commands, Example

Advertising
background image

94

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands

The XAP 800 accepts serial commands through the serial port or the expansion bus. The commands in this manual

pertain only to the XAP 800. RS-232 serial port protocol is 9,600, 19,200, 38,400 (default), or 57,600 baud; 8

bits, 1 stop bit, no parity.

Conventions

The following typographic conventions are used in this document to describe the different serial commands. Use the

Command structure section and the examples as a guide when creating your serial commands.

Convention

Description

<X>

Parameters enclosed in < > indicate a mandatory parameter.

[X]

Parameters enclosed in [ ] indicate an optional parameter.

1-8

Parameters separated by a - indicate a range between the values.

4,7,9

Parameters separated by a , indicate a list of available values.

EREF

Words in uppercase bold indicate command text.

DEVICE

Indicates the device type and device number on the expansion bus network. It is composed of a

device type character and a device number. The device type for the XAP 800 is always 5 and the

device ID will always be 0–7, or * (to select all 800 units).

Command structure

Commands can be either UPPER CASE or lower case. Also, extra spaces or tabs between arguments in text commands

are allowed. Return values are always in upper case. In order for a command to be recognized by the serial port, the

command must be terminated by a carriage return.

The structure of serial commands is as follows: #DEVICE

COMMAND [X] [X]

#

indicates the start of a command line

DEVICE

represents the device type and device number

COMMAND

is the command text

[X] [X]

represents any additional options in the order that they appear in the command descriptions that

follow

Example

A command to disable automatic gain control for Mic 2 on a XAP 800 device “0” will have the command line:

#50 AGC 2 M 0. In this command line, 5=XAP 800, 0=unit 0, AGC=command, 2=channel, M=Mic Input group, 0=off

state. If a command calls for a “null” value, leave a blank in the command line. For example, “#50 AGC 2 M” will

return the current AGC state of Mic 2 on device 50.

Command responses will have a carriage return line feed. Example: #50 AGC 2 M O carriage return line feed.