System Configuration

~ Processing

52

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

The frequency response and phase vs. frequency of the total transfer function

of all filters is displayed in the window. Each filter can be disabled without

affecting the filter settings. All filters can also be disabled using a single command.

By default, they are not enabled and the filter types are not defined. Below is a

description of each feature in the window.

Active Filter

The Active Filter displays the filter that is applied to the processing channel.

Type

Select the filter type from the Type list. Note that the configurable filter parameters

displayed depend on the selected filter type. You can use these parameters to

customize the filter, or use the mouse to click and drag the node on the graph to a

location that reflects the changes you want to make.

You can continue to add filters to the graph, and track their relationships to

each other to design a system with the sound characteristics necessary for good

audio.

Phase

Phase plots the phase response of the frequency response of the selected filter.

Bypass

Bypass All bypasses all filters.

Add Filter

Add Filter adds a filter to the graph.

Remove Filter

This removes the selected filter from the graph.

Table View

Table View toggles between the graph view and the table view. The table view allows

you to configure filters in a table format rather than on the graph, and provides an

easy way to check filter status.

Processing Channels

The Processing Channels section allows you to display the graphs of various

processing channels together, so you can view and easily modify filter and equalizer

settings throughout the frequency range. Click the respective letter to place a

processor in the graph. Click the Active processor you want to modify; it appears in

bold on the graph.