System configuration ~ inputs and outputs, P pwr (phantom power) – ClearOne XAP 800 User Manual

Page 39

Advertising
background image

33

System Configuration

~ Inputs and Outputs

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

The Speech Leveler is a compander that is optimized for speech audio. It

quickly equalizes the difference in speech levels in the room without bringing up noise.

If you use AGC with the Speech Leveler, set the AGC Response Time to >2 seconds.

AGC adjusts softer and louder input audio to a consistent level that you select

(the target level). The target level range is from -30 to 20dB in 1dB steps. The

default target level is 0dB.

Set the

Target Level first, then apply the amount of maximum gain that you

want the AGC to apply to the signal. Maximum gain range is 0 to 18dB in 1dB

steps. The default value is 18dB. AGC occurs after the gain and filter settings in

the audio signal path.

The Active Gain meter reflects the overall gain at any given moment. Click

the white box next to the meter to enable it.

The Response Time adjustment determines the total AGC engage/disengage

response time. The Threshold determines the decibel level at which you want the

AGC to engage. Setting the threshold toward the higher end of the scale (near 0)

reduces background noise to a greater degree. The Response Time is measured in

milliseconds. Target Level and Threshold are both RMS.

P Pwr (Phantom Power)

Phantom Power toggles the phantom power on and off. Phantom power is an

auxiliary power source to power certain types of microphones. The XAP 800’s

phantom power voltage is 24VDC. Default is On.

AEC

AEC opens the Acoustic Echo Canceller window. To enable the acoustic echo

canceller, click

Enabled, then select the reference. Any one of the 12 outputs, four

expansion bus references, or four virtual references can be selected.

PA Adapt and AEC Reference

If you select an expansion bus reference, the Define PA Adapt/AEC Expansion

Bus Ref window opens so you can identify which expansion bus output you want to

use as the AEC’s reference. You can also open this window from the toolbar.

Figure 3.26. AGC/Speech Leveler window

All meters in G-Ware are

peak meters. The target

level

and threshold

controls in the AGC/SL window

reflect RMS values.

✍ ✍

Figure 3.28. AEC window

Figure 3.27. Define PA/AEC

window and toolbar button

Advertising