Dfltm - default meter, Did - device id, Dspver - dsp version – ClearOne XAP 800 User Manual

Page 110: Appendices ~ appendix e: serial commands, Argument details

Advertising
background image

Appendices

~ Appendix E: Serial Commands

104

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

DFLTM - Default Meter

This command selects/reports the setting of the default meter.

Command form: DEVICE DFLTM [Channel] [Group] [Position]

Argument details

Name

Description

Device

0–7 or * to select all units

DFLTM

Command form

Channel

1–12

Group

I = Inputs, O = Outputs, M = Mic Inputs, L= Line Inputs

Position

I, A, N, G, as applicable for group

(see Meter Type definitions, page 98)

Example:

#55 DFLTM 8 O A On XAP 800 unit 5 (#55), the default meter

(DFLTM) is set to output (O) 8 after the gain adjustment (A).

DID - Device ID

This command selects/reports the device ID.

Command form:

DEVICE DID [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

DID

Command form

Value

0–7 (select device ID)

Example:

#57 DID 0 On XAP 800 unit 7 (#57), the device ID (DID) is set to 0.

DSPVER - DSP Version

This command reports the version of the DSP code in the unit. the version is a date

and time stamp. This command is read only.

Command form: DEVICE DSPVER [value]

Argument details

Name

Description

Device

0–7 or * to select all units

DSPVER

Command form

Value

Null

Example

: #55 DSPVER The XAP 800 unit 5 (#55) will return the DSP version

(DSPVER).