Compress - compressor adjust, Compsel - compression select, Appendices ~ appendix e: serial commands – ClearOne XAP 800 User Manual

Page 108: Argument details

Advertising
background image

Appendices

~ Appendix E: Serial Commands

102

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

COMPRESS - Compressor Adjust

This command selects/reports the setting of the compressor on processing channels.

Command form

DEVICE COMPRESS <Channel> [Threshold] [Ratio] [Attack]

[Release] [Gain]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

COMPRESS

Command form

Channel

Range A–H (selects processing channel)

Threshold

-30 to 20, Null to return current value

dB

Ratio

1 to 20

Attack

0.00 to 100.00 (select in .5ms intervals)

ms

Release

100 to 2000 (select in 5ms intervals)

ms

Gain

0.00 to 20.00

dB

Example:

#51 COMPRESS A 6 5 25 250 3 On XAP 800 unit 1 (#51), the

compression (COMPRESS) within processing channel A is set to have a threshold

of 6dB, a ratio of 5:1 (5), an attack time of 25ms, a release time of 250ms, and a

gain of 3dB.

COMPSEL - Compression Select

This command selects/reports the compressor activation of each assignable

processing channel.

Command form:

DEVICE COMPSEL <Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

COMPSEL

Command form

Channel

Range A–H (selects processing channel)

Value

0 = Off, 1 = On, 2 = Toggle, Null returns current state

Example:

#50 COMPSEL A 1 On XAP 800 unit 0 (#50), the compression

(COMPSEL) within processing channel A is set on (1).