Control

~ RS-232 Port

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Command strings

By creating command strings, you can use your XAP 800 to control equipment such

as lighting, projectors, and room dividers as well as other ClearOne products. A

command string is passed to the connected device via the XAP 800’s RS-232 port.

You can create up to eight customized serial command strings (limit 80 characters

each) in the Command Strings window. To open the Command Strings window, click

the Command Strings toolbar button.

To create a command string

Type the serial command string (limit 80 characters) in one of the eight

locations. The command string will support special characters. See list at

right.

To run a command string

Use any external control device (e.g. Control Panel, GPIO control) to run the

STRING serial command.

– or –

Incorporate the STRING command into a macro which can be run from

G-Ware, the front panel, or any external control device.

For information on creating macros, see page 63. For information on GPIO builder,

see page 77. For information on Control Panels, see page 79.

Figure 6.7. Command

Strings toolbar button

Figure 6.8. Command Strings window

Special characters

\a = alert

\b = backspace

\f = formfeed

\n = new line

\r = carriage return

\t = horizontal tab

\v = vertical tab

\\ = backslash